2101
Key features:
Extremely accurate
Robust big foot
Alloy steel or Stainless steel structure
Full laser welded bending beam load cell
3000 divisions OIML R60 class C
Auto temperature compensated
Standard with 2.0mV/V sensitivity and 4-wire connection
Ideal for platforms, hoppers and silo scales
Safety overloading: 150%, Breaking Overload: 300%
Fully laser welded for harsh industrial environment
High quality nickel plated with strong corrosion resistant
DIMENSIONS

SPECIFICATIONS
| Items | C3 C4 C5 C6 | Unit |
| Combined error | 0.015 0.012 0.01 0.008 | %Emax |
| Rated Capacity | 0.1, 0.5, 1,2, 3, 5, 8, 10 | Ton |
| Rated Output | Analog 2.0mV/V ± 0.1% Digital 1,000,000d | |
| Zero Output | < 1.0 | %Cn |
| Non-linearity | < 0.01 | %Cn |
| Repeatability | < 0.005 | %Cn |
| Hysteresis Error | < 0.015 < 0.0125 < 0.010 < 0.008 | %Cn |
| Creep | < 0.015 < 0.0125 < 0.010 < 0.008 | %Cn |
| Temperature Effect on sensitivity(Tkc) | < 0.010 < 0.008 < 0.007 < 0.005 | %Cn/k |
| Temperature Effect on zero balance(Tko) | < 0.010 < 0.007 < 0.007 < 0.007 | %Cn/k |
| Input Resistance | 385 ±5 | Ω(Ohms) |
| Output Resistance | 351 ± 2 | Ω(Ohms) |
| Insulation Resistance | > 5000 | MΩ (50V DC) |
| Safe Overload | 150 | %F.S |
| Breaking Overload | 300 | %F.S |
| Working Temperature Range | -20~ +70 /-20 ~ +160 | °C/°F |
| Recommended Excitation | 8~15 | V (DC or AC) |
| Maximum Excitation | 24 | V (DC or AC) |
| Material of elastomer | Alloy steel / Stainless steel | |
| Protection level | IP68 / IP69 / IP69K | |
| Cable | 0.5t~3t: 3m; 5t~8t: 6m; 10t: 8m; 20t: 10m; | |
| Standard | GB/T7551-2008 OIML R60 | |
WIRING CODE

PACKAGING(CARTON)
| Rated capacity | 0.1~3t | 5t | 10t |
| Net.w per carton | 1.3kg*10 | 2.4kg*4 | 3.8kg*2 |
| Volume | 0.41*0.21*0.21m³/0.7kg | ||